ARM: dts: uniphier: Add missing cooling device properties for CPUs
The cooling device properties, like "#cooling-cells" and "dynamic-power-coefficient", should either be present for all the CPUs of a cluster or none. If these are present only for a subset of CPUs of a cluster then things will start falling apart as soon as the CPUs are brought online in a different order. For example, this will happen because the operating system looks for such properties in the CPU node it is trying to bring up, so that it can register a cooling device. Add such missing properties. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Masahiro Yamada <yamada.masahiro@socionext.com>
This commit is contained in:
parent
ce397d215c
commit
38dc27c85e
1 changed files with 3 additions and 0 deletions
|
@ -36,6 +36,7 @@
|
|||
enable-method = "psci";
|
||||
next-level-cache = <&l2>;
|
||||
operating-points-v2 = <&cpu_opp>;
|
||||
#cooling-cells = <2>;
|
||||
};
|
||||
|
||||
cpu2: cpu@2 {
|
||||
|
@ -46,6 +47,7 @@
|
|||
enable-method = "psci";
|
||||
next-level-cache = <&l2>;
|
||||
operating-points-v2 = <&cpu_opp>;
|
||||
#cooling-cells = <2>;
|
||||
};
|
||||
|
||||
cpu3: cpu@3 {
|
||||
|
@ -56,6 +58,7 @@
|
|||
enable-method = "psci";
|
||||
next-level-cache = <&l2>;
|
||||
operating-points-v2 = <&cpu_opp>;
|
||||
#cooling-cells = <2>;
|
||||
};
|
||||
};
|
||||
|
||||
|
|